Common Errors in Magnetic Field Line Diagrams (NCERT Example 5.3)
On this page· 13 sections
Source & scope. Class 12 Physics, Chapter 5 Magnetism and Matter, Section 5.2.1, built entirely around the worked Example 5.3. This article applies the four field-line properties from [Properties of Magnetic Field Lines](/study-materials/phy12-ch05-properties-of-magnetic-field-lines) and the closed-...
Source & scope. Class 12 Physics, Chapter 5 Magnetism and Matter, Section 5.2.1, built entirely around the worked Example 5.3. This article applies the four field-line properties from [Properties of Magnetic Field Lines](/study-materials/phy12-ch05-properties-of-magnetic-field-lines) and the closed-loop consequence from Why Magnetic Monopoles Do Not Exist to seven classic diagram-judging scenarios, turning the rules into a fast diagnostic students can run on any field-line picture.
NCERT Example 5.3 presents seven classic magnetic-field-line diagrams and asks which are physically correct, testing whether a student can apply the defining rules of field lines — never emanating from a point, never crossing, always closed around a current-carrying region, and always giving zero net flux through any closed surface — to catch deliberately wrong diagrams, several of which actually depict valid electrostatic field lines instead. Two diagnostic rules do almost all of the work: a magnetic field line can never start or end at a point (because there is no magnetic monopole to act as a source or sink), and a closed magnetic field loop must always enclose a current (unlike an electrostatic loop, which can never close at all).
At a glance
- Magnetic field lines can never emanate from a single point — doing so would require a nonzero flux through a tiny closed surface around that point, which violates Gauss's law of magnetism.
- A closed magnetic field loop must enclose a current-carrying region — e.g. the loops confined inside a toroid are valid because each one encloses current.
- Electrostatic field lines never form closed loops, whether or not the loop encloses charge — this is a point of contrast, not similarity, with magnetic field lines.
- Field lines cannot be perfectly straight and abruptly confined at the ends of a solenoid or between the pole pieces of a magnet — some curving/fringing is unavoidable, or Ampère's law is violated.
- Not every line needs to emanate from the N pole or converge into the S pole of a bar magnet — the net flux through a surface around either pole alone is still zero.
Learning objectives
- State the diagnostic rules that any valid magnetic field line diagram must obey.
- Apply those rules to classify each of the seven configurations in NCERT Example 5.3 as right or wrong.
- Explain why several "wrong" magnetic diagrams are in fact correct depictions of electrostatic field lines instead.
- Explain why straight, sharply-confined field lines at the ends of a solenoid or between pole pieces violate Ampère's law.
Prerequisite knowledge
The reader should already know the four properties of magnetic field lines (closed loops, tangent = field direction, density = field strength, never cross) and the reason magnetic monopoles' absence forces field lines to close — both covered in the two preceding articles — plus a basic sense of how electrostatic field lines behave around point charges and charged plates.
Core explanation
The diagnostic rules
Before judging any diagram, two rules settle almost every case:
- No field line can emanate from, or converge into, a single point in empty space. A point source or sink of field lines is exactly what a magnetic monopole would be — and since monopoles don't exist, no closed surface can ever enclose a nonzero net magnetic flux. A diagram showing lines radiating outward from one point in all directions (like spikes from a dot) is not describing a magnetic field at all.
- A closed magnetic field loop must enclose a current-carrying region. Static magnetic field lines are produced by currents (or, equivalently, by magnetic materials), so a closed loop of magnetic field line floating in otherwise empty space, with no current passing through the area it encloses, cannot be a valid magnetic field line.
A useful side-fact sharpens rule 2 further: electrostatic field lines can never form closed loops at all — not around empty space, and not even around a region that does enclose electric charge. So "forms a closed loop" is, by itself, never valid for an electric field diagram, while for a magnetic field diagram it is valid precisely when the loop encloses a current.
Applying the rules to the seven configurations
NCERT's Example 5.3 presents seven diagrams (labelled a–g) and asks which are wrong, and why. Each is reasoned through below.
(a) Field lines radiating straight outward from a single point in all directions, like spikes from a dot — wrong. Magnetic field lines can never emanate from a point; by rule 1, this is impossible for a magnetic field. The picture is in fact a valid description of the electric field around a long, positively charged straight wire. The correct magnetic field lines for a straight current-carrying conductor are concentric circles encircling the wire, not radiating away from it.
(b) Two field lines shown crossing each other, and also forming a closed loop around empty space — wrong, with two separate errors. First, magnetic (like electric) field lines can never cross one another, since the field direction at the crossing point would be ambiguous. Second, a closed magnetostatic field loop can never enclose empty space with no current passing through it — a valid closed magnetic loop must always enclose a region through which a current flows. (By contrast, electrostatic field lines can never form closed loops at all, whether or not charge is enclosed — so this configuration could not be rescued as an electric-field diagram either.)
(c) Field lines completely confined within the inside of a toroid, forming closed loops — right. Nothing is wrong here: each closed loop of field line lies entirely inside the toroid and encloses a region through which the toroid's winding current passes, exactly satisfying rule 2.
(d) Field lines of a solenoid drawn perfectly straight and sharply confined right up to, and beyond, both ends — wrong. Field lines at and beyond the ends of a real solenoid cannot be so completely straight and abruptly cut off; such a picture would violate Ampère's law. In reality, the lines must curve outward at both ends and eventually bend around to meet and form closed loops, rather than terminating or staying perfectly parallel outside the solenoid.
(e) Field lines shown both outside and inside a bar magnet, with not every line emanating from the N pole or converging into the S pole — right. This is correct: it is not required that every single field line visibly emanate from the N pole or converge into the S pole in a 2-D sketch. Around both the N pole and the S pole individually, the net flux of the field is still zero, consistent with Gauss's law of magnetism — some lines simply loop more locally near a pole rather than crossing the whole external space.
(f) Field lines all appearing to emanate outward from a single shaded plate — wrong. These cannot be magnetic field lines: the net flux through a surface surrounding the shaded plate is clearly not zero in the picture (everything streams away from it), which is impossible for a true magnetic field (rule 1, generalised from a point to an extended source). The picture is, in fact, a valid depiction of the electrostatic field lines running from a positively charged upper plate to a negatively charged lower plate.
(g) Field lines between two pole pieces of a magnet, drawn perfectly straight right up to the edges with no fringing at all — wrong. Field lines between two pole pieces cannot be exactly straight all the way to the ends; some fringing (curving outward near the edges) is unavoidable — a perfectly straight, abruptly-terminated field would again violate Ampère's law. NCERT notes this is equally true for the analogous electric-field case between two charged plates: real electric field lines also fringe at the edges rather than staying perfectly straight and confined.
The underlying pattern across all seven
Six of the seven cases are deliberately engineered traps built from the same two rules: (a), (b), (f) violate the "no point source/sink, no net flux through any closed surface" rule in various disguises (one of them, (b), stacking a second, independent crossing-lines error on top); (d) and (g) violate Ampère's law by forcing field lines to be unrealistically straight and sharply cut off; only (c) and (e) are genuinely correct. Several of the "wrong" magnetic pictures — (a) and (f) — are, read as electric field diagrams instead, perfectly valid, which is precisely the point: the exercise trains a reader to recognise that electrostatic and magnetostatic field-line pictures are easy to mix up on paper but obey different closure and flux rules.
Key terms
- Point source/sink (field lines) — a single point from which field lines are shown radiating or converging; valid for an isolated electric charge, never valid for a magnetic field.
- Toroid — a solenoid bent into a closed ring shape, whose field is confined entirely within the ring, each internal loop enclosing the winding current.
- Fringing — the slight outward curving of field lines near the edge of a finite solenoid or between pole pieces, instead of staying perfectly straight and confined.
- Ampère's law (role here) — the law that constrains how magnetic field lines must behave near current-carrying boundaries; violated by unrealistically straight, abruptly-terminated field lines.
- Net flux through a closed surface — the quantity that Gauss's law of magnetism requires to be exactly zero for any valid magnetic field configuration.
Diagram / figure guidance
Because the seven original figures cannot be reproduced here, describe each as a labelled panel for an editor/illustrator to redraw: (a) arrows radiating straight outward from a single dot in all directions, like the spikes of a star; (b) two curved lines crossing in an X shape while also looping closed around a blank region; (c) a ring (toroid) cross-section with small closed loops entirely inside the ring's body; (d) a cylinder (solenoid) with perfectly straight parallel lines running through it and continuing unbent past both open ends; (e) a bar magnet with curved lines both inside and outside it, some looping back near a pole rather than all reaching the opposite pole; (f) a single flat shaded rectangle (plate) with arrows radiating outward from every point on its surface in all directions; (g) two flat parallel pole-face rectangles facing each other with dead-straight vertical lines between them, including right at the edges with no outward curve.
Worked example
Example 5.3 (NCERT): examine each of the seven field-line diagrams described above and state which are wrong, which are right, and why — noting that some may correctly describe electrostatic field lines instead.
Worked fully in the Core explanation section above, part by part: (a) wrong — a magnetic field cannot radiate from a point (rule 1); it is instead the valid electric field of a long charged wire, whereas the true magnetic field there consists of circles around the wire. (b) wrong, on two independent counts — field lines cross (always forbidden) and the closed loop encloses no current (forbidden for a magnetic loop; and note an electrostatic loop could never close either way). (c) right — closed loops confined inside a toroid each enclose the winding current, exactly as required. (d) wrong — a solenoid's field cannot stay perfectly straight and sharply cut off beyond its ends; this would violate Ampère's law, and the real lines must curve out and close up. (e) right — not every line needs to run pole-to-pole; the net flux around each pole individually is still zero. (f) wrong — flux streaming outward from an extended shaded plate with nonzero net flux is impossible magnetically; it is instead the valid electrostatic field between a positive and a negative plate. (g) wrong — perfectly straight field lines with no fringing at the edges between pole pieces again violates Ampère's law; some curving at the edges is unavoidable, and the same fringing applies to the analogous electric-field case.
Common misconceptions
- "If a diagram looks like a valid field pattern, it's probably a valid magnetic field pattern." Several of the classic wrong diagrams are in fact perfectly valid electrostatic field patterns (radiating from a point charge, or running plate-to-plate) — the shape alone doesn't tell you which kind of field it is; the closure and flux rules do.
- "A closed loop of field lines is always suspicious because closed loops are rare." The opposite is true for magnetism: every valid magnetostatic field line is a closed loop; what's suspicious is a closed loop that encloses no current, or any electrostatic diagram that closes at all.
- "Field lines inside a solenoid or between pole pieces should be perfectly straight for a 'clean' diagram." Perfectly straight, abruptly-terminated lines actually violate Ampère's law — some fringing/curvature at the edges and ends is physically required, not a drawing imperfection to be corrected away.
- "If every field line doesn't visibly connect the N pole to the S pole, the diagram must be wrong." It doesn't have to — Example 5.3(e) is correct precisely because the net flux around each pole is zero without every single line needing to run the full external path from N to S.
Exam application (NEET & JEE)
This exact "spot the wrong field-line diagram" format, lifted directly from Example 5.3, is one of the most reliably recurring conceptual question types on magnetism in NEET and JEE — usually given as a set of described or sketched configurations with a request to identify which are physically impossible and why. The two diagnostic rules (no point source/sink; closed loops must enclose current) and the Ampère's-law-based fringing argument are the fast checks examiners expect; questions also frequently test whether a student notices that a "wrong" magnetic diagram is secretly a valid electrostatic one.
Frequently asked questions
- Can magnetic field lines radiate straight outward from a single point, like an electric charge's field? No — this would require a magnetic monopole acting as a source, which does not exist; such a radiating pattern can only be a valid electric field line diagram, not a magnetic one.
- Is it ever correct for magnetic field lines to form a closed loop around completely empty space with no current? No — a valid closed magnetostatic loop must always enclose a region through which a current passes; a loop around current-free empty space is not physically valid.
- Why can't magnetic field lines be perfectly straight at the ends of a solenoid? Because perfectly straight, abruptly-terminated lines there would violate Ampère's law; the real field lines must curve outward near the ends and eventually close into loops.
- Does every field line around a bar magnet have to run all the way from the north pole to the south pole? No — it is enough that the net flux around each pole individually is zero; not every single line needs to visibly connect both poles in a diagram.
- How can you tell whether a described field-line diagram is secretly describing an electric field rather than a magnetic one? Check whether lines emanate from or converge into a single point/plate (valid only for electric fields) or form a closed loop (valid only for magnetic fields, and only if it encloses a current) — these closure/flux behaviours are the key discriminator.
Practice questions (original practice questions)
- A diagram shows field lines radiating straight outward in all directions from a single point with no current anywhere nearby. This diagram:
- (a) is a valid magnetic field
- (b) cannot be a magnetic field, but can be a valid electric field of a point charge
- (c) is valid only inside a solenoid
- (d) is valid only for a toroid
- Answer: (b) — A point source of field lines requires a monopole, which does not exist for magnetism; it correctly describes an isolated point charge's electric field.
- A closed loop of magnetic field line is drawn enclosing a region through which no current passes. This loop is:
- (a) valid, since magnetic field lines are always closed
- (b) invalid, because a closed magnetic loop must enclose a current-carrying region
- (c) valid only if it is circular
- (d) valid only outside a magnet
- Answer: (b) — Closure alone is not sufficient; the enclosed region must carry a current.
- Inside a toroid, the magnetic field lines form closed loops confined entirely within the ring. This configuration is:
- (a) wrong, since field lines cannot be confined
- (b) wrong, since closed loops are never valid
- (c) right, since each loop encloses the winding current
- (d) right, but only if the toroid is very large
- Answer: (c) — Each internal loop encloses the toroid's current, satisfying the closed-loop requirement.
- Field lines drawn perfectly straight and sharply cut off right at the open end of a solenoid, with no curving at all, would violate:
- (a) Gauss's law of magnetism only
- (b) Ampère's law
- (c) Coulomb's law
- (d) Newton's third law
- Answer: (b) — Such an idealised, unfringed termination is inconsistent with Ampère's law; real lines must curve and close.
- A diagram shows field lines both inside and outside a bar magnet, where not every single line runs all the way from the N pole to the S pole. This diagram is:
- (a) definitely wrong
- (b) right, since the net flux around each pole individually is still zero
- (c) right only if redrawn with every line reaching the opposite pole
- (d) wrong, since NCERT requires every line to connect both poles
- Answer: (b) — This is exactly NCERT Example 5.3(e) — it is a correct diagram.
Quick revision
- Rule 1: magnetic field lines can never emanate from or converge into a point (no monopole exists to act as source/sink).
- Rule 2: a closed magnetic field loop must always enclose a current-carrying region.
- Electrostatic field lines never close, with or without enclosed charge — a different rule from magnetism's.
- Example 5.3: (a) wrong (point source — valid as E field of a wire instead), (b) wrong (crossing + empty-space loop), (c) right (toroid, encloses current), (d) wrong (unfringed solenoid ends, violates Ampère's law), (e) right (not every line need join N to S), (f) wrong (plate source — valid as E field between charged plates instead), (g) wrong (unfringed pole-piece field, violates Ampère's law).
- Fringing (slight curving at edges/ends) is physically required, not a flaw to "fix" in a diagram.
Related articles
- Builds on: Properties of Magnetic Field Lines
- Builds on: Why Magnetic Monopoles Do Not Exist
- See also: The Bar Magnet: Basic Properties and Poles
- Related topics: Axial Magnetic Field of a Bar Magnet, Bar Magnet as an Equivalent Solenoid, Classification of Magnetic Materials by Susceptibility, Diamagnetism, Domain Theory of Ferromagnetism, Effect of Temperature on Ferromagnetism (Curie Point)