Transformer Energy Loss: Hysteresis in the Core
On this page· 13 sections
Source & scope. Class 12 Physics, Chapter 7 Alternating Current, Section 7.8 Transformers. This is the fourth and last of four articles on real transformer energy losses. Builds on: Transformer: Principle and EMF Equations. See also: Transformer Energy Loss: Flux Leakage, Transformer Energy Loss: Re...
Source & scope. Class 12 Physics, Chapter 7 Alternating Current, Section 7.8 Transformers. This is the fourth and last of four articles on real transformer energy losses. Builds on: Transformer: Principle and EMF Equations. See also: Transformer Energy Loss: Flux Leakage, Transformer Energy Loss: Resistance of the Windings, Transformer Energy Loss: Eddy Currents in the Core.
Hysteresis loss in a transformer is the energy dissipated as heat each cycle because the magnetisation of the iron core is repeatedly reversed by the alternating magnetic field. NCERT states that this loss is kept to a minimum by choosing a magnetic material for the core that has low hysteresis loss.
At a glance
- NCERT's statement: the core's magnetisation is repeatedly reversed by the alternating field, and the resulting expenditure of energy appears as heat.
- Remedy (NCERT): use a magnetic material with low hysteresis loss for the core.
- Physically, the magnetic domains in the core material lag behind the rapidly reversing applied field.
- The area enclosed by the B–H hysteresis loop corresponds to the energy dissipated as heat per cycle.
- "Soft" ferromagnetic materials (soft iron, transformer steel alloys) have a narrow loop (low coercivity) and are chosen for transformer cores, unlike "hard" materials used for permanent magnets.
Learning objectives
- State what hysteresis loss is and why repeatedly reversing the core's magnetisation dissipates energy.
- Relate the area of the B–H hysteresis loop to the energy lost per cycle.
- Explain why "soft" magnetic materials are chosen for transformer cores rather than "hard" ferromagnetic materials.
- Distinguish hysteresis loss from the other three named transformer losses.
Prerequisite knowledge
The reader should already know that ferromagnetic materials like iron can be magnetised by an external magnetic field, and that this magnetisation does not respond instantaneously or perfectly reversibly to a changing applied field — this lag is the basis of hysteresis.
Core explanation
What hysteresis loss is
In a transformer, the iron core is subjected to a magnetic field that reverses direction twice every cycle, following the applied alternating voltage. NCERT states this directly: the magnetisation of the core is repeatedly reversed by the alternating magnetic field, and the resulting expenditure of energy in the core appears as heat. This heat generation is called hysteresis loss, and — unlike eddy-current loss, which arises from induced circulating currents — hysteresis loss arises from the intrinsic magnetic behaviour of the core material itself as its internal magnetisation is forced to reverse again and again.
Why reversing magnetisation dissipates energy
A ferromagnetic material like iron is made up of many microscopic magnetic domains, tiny regions each magnetised in a particular direction. When an external field is applied, these domains realign to follow the field, but they do not realign instantaneously or without resistance — there is internal friction-like opposition as domain boundaries shift and domains rotate. As a result, the material's magnetisation lags behind the rapidly reversing applied field, a phenomenon known as hysteresis ("lagging behind"). If the magnetic flux density in the core is plotted against the applied field over a full cycle, the resulting curve does not retrace itself exactly — instead, it traces out a closed loop, known as the hysteresis loop, because the value of for a given depends on whether the field is increasing or decreasing at that moment. The area enclosed by this B–H loop for one full cycle corresponds exactly to the energy dissipated as heat in the core material during that cycle; the larger the enclosed area, the greater the hysteresis loss per cycle.
The low-hysteresis-material remedy
Because hysteresis loss occurs once every cycle regardless of eddy currents or winding resistance, the only way to reduce it is to use a core material whose B–H loop encloses a small area — that is, a material with inherently low hysteresis loss. NCERT states that this loss is kept to a minimum by using a magnetic material that has low hysteresis loss. Ferromagnetic materials are broadly classified as "soft" or "hard": soft ferromagnetic materials, such as soft iron and specially-alloyed transformer steels, have a narrow hysteresis loop and low coercivity (they are easily and almost fully demagnetised once the external field is removed), which means a small enclosed loop area and therefore low energy dissipation per cycle. Hard ferromagnetic materials, by contrast, retain their magnetisation strongly and have a wide hysteresis loop with high coercivity — these are exactly the materials deliberately chosen to make permanent magnets, not transformer cores, because a transformer core must repeatedly and easily reverse its magnetisation every cycle without "fighting" the applied field.
Key terms
- Hysteresis loss — the energy dissipated as heat each cycle because the core's magnetisation lags behind and must be repeatedly reversed by the alternating field.
- Magnetic domain — a microscopic region of a ferromagnetic material with a uniform direction of magnetisation; domains realign (with internal opposition) in response to an external field.
- B–H hysteresis loop — the closed curve traced by plotting flux density against applied field over one full cycle of magnetisation reversal; its enclosed area equals the energy dissipated per cycle.
- Coercivity — a measure of how strongly a material resists demagnetisation; low-coercivity ("soft") materials are easily demagnetised and have narrow hysteresis loops.
- Soft ferromagnetic material — a material (e.g., soft iron, transformer steel) with low coercivity and low hysteresis loss, used for transformer cores.
- Hard ferromagnetic material — a material with high coercivity and a wide hysteresis loop, used for permanent magnets rather than transformer cores.
Diagram / figure guidance
Draw two B–H hysteresis loops side by side for comparison. Left: a narrow, thin loop labelled "soft magnetic material (e.g., transformer core)," with a small shaded enclosed area labelled "small energy loss per cycle." Right: a wide, fat loop labelled "hard magnetic material (e.g., permanent magnet)," with a much larger shaded enclosed area labelled "large energy loss per cycle if used in a transformer." Axes should be labelled (flux density) on the vertical axis and (applied field) on the horizontal axis.
Worked example
A transformer core material has a B–H hysteresis loop enclosing an area corresponding to an energy dissipation of J per cycle per unit volume of core material, when operated at 50 Hz. If the core has a volume of , estimate the hysteresis power loss in the core.
Energy dissipated per cycle in the whole core J per cycle.
At 50 Hz, the magnetisation reverses through a full cycle 50 times per second, so the hysteresis power loss is:
So this core dissipates about 0.01 W as hysteresis loss. A core material with a narrower B–H loop (lower energy-per-cycle figure) would give a proportionally smaller hysteresis loss at the same frequency and volume — which is exactly why transformer cores are built from low-hysteresis ("soft") magnetic materials rather than high-hysteresis ones.
Common misconceptions
- "Hysteresis loss and eddy-current loss have the same cause." They do not — eddy-current loss comes from induced circulating currents in the conducting core, reduced by laminating the core, while hysteresis loss comes from the intrinsic lag of the core material's magnetisation behind the applied field, reduced by choosing a low-hysteresis material; they are separate mechanisms with separate remedies.
- "Laminating the core also reduces hysteresis loss." Laminating specifically targets eddy currents by confining their loops to thin sheets; it does not change the intrinsic hysteresis behaviour of the core material itself, which depends on the material's magnetic properties, not its geometry.
- "Any iron core has the same hysteresis loss." Different magnetic materials have very different hysteresis-loop areas; "soft" materials like soft iron or specially-alloyed transformer steel are deliberately chosen for transformer cores because they have narrow loops and low hysteresis loss, unlike "hard" ferromagnetic materials used for permanent magnets.
- "A material with high coercivity (good for permanent magnets) is also good for transformer cores." The opposite is true — a transformer core must easily and repeatedly reverse its magnetisation every cycle, so a low-coercivity ("soft") material is required; high-coercivity ("hard") materials resist demagnetisation and would cause large hysteresis losses if used in a transformer core.
Exam application (NEET & JEE)
NEET and JEE test hysteresis loss conceptually — asking students to identify the cause (repeated reversal of the core's magnetisation) and the remedy (a low-hysteresis-loss magnetic material) — and sometimes via the B–H loop, asking what the enclosed loop area represents physically (energy dissipated per cycle). Questions frequently pair this with eddy-current loss in "distinguish the following two losses" items, since both occur in the core but arise from different physical mechanisms and have different remedies (material choice versus lamination).
Frequently asked questions
- What is hysteresis loss in a transformer? Hysteresis loss is the energy dissipated as heat each cycle because the alternating magnetic field repeatedly reverses the magnetisation of the transformer's iron core.
- How is hysteresis loss minimised in a transformer? NCERT states that hysteresis loss is kept to a minimum by using a magnetic material for the core that has low hysteresis loss.
- What does the area of the B–H hysteresis loop represent? The area enclosed by the B–H hysteresis loop for one full cycle corresponds to the energy dissipated as heat in the core material during that cycle.
- Why are "soft" magnetic materials used for transformer cores? Soft ferromagnetic materials, such as soft iron and transformer steel alloys, have a narrow hysteresis loop and low coercivity, so they can be easily and repeatedly demagnetised and remagnetised each cycle with low energy loss.
- Is hysteresis loss the same as eddy-current loss? No — hysteresis loss arises from the core material's magnetisation lagging behind the reversing applied field, while eddy-current loss arises from induced circulating currents in the conducting core; they are distinct mechanisms with distinct remedies.
Practice questions (original practice questions)
- Hysteresis loss in a transformer core occurs because:
- (a) the winding wire has resistance
- (b) the core's magnetisation is repeatedly reversed by the alternating field
- (c) flux leaks out of the core
- (d) eddy currents flow in the windings
- Answer: (b)
- The energy dissipated per cycle due to hysteresis corresponds to:
- (a) the slope of the B–H curve
- (b) the area enclosed by the B–H hysteresis loop
- (c) the maximum value of B
- (d) the frequency of the applied field
- Answer: (b)
- To minimise hysteresis loss, a transformer core should be made of a material with:
- (a) high coercivity
- (b) a wide hysteresis loop
- (c) low hysteresis loss (narrow loop, low coercivity)
- (d) high electrical resistance only
- Answer: (c)
- Materials used for permanent magnets, compared to transformer cores, typically have:
- (a) lower coercivity and narrower hysteresis loops
- (b) higher coercivity and wider hysteresis loops
- (c) identical hysteresis loops
- (d) no hysteresis loop at all
- Answer: (b)
- Which remedy specifically addresses hysteresis loss, as distinct from eddy-current loss?
- (a) laminating the core
- (b) choosing a low-hysteresis magnetic material for the core
- (c) using thick winding wire
- (d) winding coils one over the other
- Answer: (b)
Quick revision
- Hysteresis loss: heat from repeatedly reversing the core's magnetisation each cycle.
- Energy dissipated per cycle = area enclosed by the B–H hysteresis loop.
- Remedy: use a core material with low hysteresis loss.
- "Soft" magnetic materials (soft iron, transformer steel) have narrow loops, low coercivity — used for cores.
- "Hard" magnetic materials have wide loops, high coercivity — used for permanent magnets, not cores.
Related articles